2024-04-02 カーネギーメロン大学
New work by researchers at CMU and the Indian Institute of Technology (IIT) Gandhinagar shows that adding an inexpensive thermal camera to wearable devices could substantially improve how accurately they estimate calories burned.
<関連情報>
JoulesEye: 運動中の熱画像からのエネルギー消費量推定と呼吸検知。 JoulesEye: Energy Expenditure Estimation and Respiration Sensing from Thermal Imagery While Exercising
Rishiraj Adhikary,Maite Sadeh,Nipun Batra,Mayank Goel
Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies Published:12 January 2024
DOI:https://doi.org/10.1145/3631422
Abstract
Smartphones and smartwatches have contributed significantly to fitness monitoring by providing real-time statistics, thanks to accurate tracking of physiological indices such as heart rate. However, the estimation of calories burned during exercise is inaccurate and cannot be used for medical diagnosis. In this work, we present JoulesEye, a smartphone thermal camera-based system that can accurately estimate calorie burn by monitoring respiration rate. We evaluated JoulesEye on 54 participants who performed high intensity cycling and running. The mean absolute percentage error (MAPE) of JoulesEye was 5.8%, which is significantly better than the MAPE of 37.6% observed with commercial smartwatch-based methods that only use heart rate. Finally, we show that an ultra-low-resolution thermal camera that is small enough to fit inside a watch or other wearables is sufficient for accurate calorie burn estimation. These results suggest that JoulesEye is a promising new method for accurate and reliable calorie burn estimation.